top of page

882IS Intrinsically Safe Digital Weight Indicator

882IS Intrinsically Safe Digital Weight Indicator

Download Detailed Brochure

882IS Intrinsically Safe Digital Weight Indicator

SAFE, ACCURATE WEIGHT READINGS IN HAZARDOUS LOCATIONS 


The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications. The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements. 


ENHANCED CONNECTIVITY 


Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module. To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator.

Features

  • 0.8in, seven-digit, seven-segment LCD display with white LED backlight

  • Stainless steel IP66 enclosure

  • T4 temperature rating

  • Battery life display icon

  • Excitation for four 350-ohm or eight 700-ohm load cells

  • Tilt stand

  • Numeric keypad (882IS Plus only)

  • Duplex fiber optic interface

  • Power ON/OFF; battery save mode

  • Configurable local/remote mode

  • I/O module option: one serial port, optional analog output, optional fieldbus cards, Ethernet TCP/IP

  • Time & date (requires I/O module)

  • Setpoint functionality with remote indicator

  • FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file number 180948

Specifications

Load Cell Excitation:
3.0 VDC at 87.5 Ω, 4.6 VDC at 700 Ω

Load Cell Current:
34 mA (4 x 350 Ω load cells) or (8 x 700 Ω load cells)

Load Cell Cabling:
Four and six-wire with remote sensing (recommended)

Analog Signal Input Range:
0.6 mV/V - 4.0 mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

Conversion Rate:
60 updates/second

Resolution:
10,000 displayed graduations (NTEP Certified),
1,000,000 expanded
The maximum number of allowed graduations will vary by application

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 x 24 dot
matrix messaging area with white LED backlight

Decimal Point:
Configurable with dead zeros

Unit Switching:
Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values

Front Panel Control Switches:
882IS:
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad

Front Panel:
Ten-button plus power button flat membrane panel

Front Panel Annunciators:
Center Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off)

Power Input:
5.8-7.9 VDC,100-175 mA
Maximum power consumption 0.25 watts

Operating Temperature:
14° F to 104° F (-10° C to 40° C) legal

Electrical Operating Temperature:
14° F to 104° F (-10° C to 40° C) legal

Rating/Material:
Stainless steel IP66 enclosure

Optional Battery:
Operating times: 4 x 350 Ω = 60 hrs.
1 x 350 Ω = 80-100 hrs. Charging times: 8-10 hrs

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited warranty

Intrinsic Safety:
FM/cFM:
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T135°C Da
Ta = -10°C to +40°C (14°F to 104°F)
ATEX/IECEx:
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T135°C Da

Approvals:
UL/cUL Listed*
FM Entity
ATEX
IECEx
NTEP
Measurement Canada

*UL is only applicable to 882IS I/O and battery charger

bottom of page